1. The output force of the rodless cylinder is insufficient and the movement is unstable during operation
Cause of failure: Generally, it is because the piston or piston rod is stuck. The main reasons are insufficient lubrication, insufficient air supply, or condensed water and impurities in the cylinder. caused by other reasons.
Solution: Adjust the center of the piston rod;check whether the oil mist device is working properly;whether the air supply pipeline is blocked;if condensation is found in the rodless cylinder When there is water and impurities, we should remove them in time.
2. The rodless cylinder has poor buffering effect
Cause of failure: Generally, the buffer seal ring is worn or the adjusting screw is damaged.
Solution: Replace the sealing ring and adjusting screw.
3. The rodless cylinder has internal and external leakage problems
Cause of failure: The general reason is that the piston rod is installed eccentrically or the lubricating oil supply in the cylinder is insufficient. The sealing ring and sealing ring are worn or damaged. It may also be caused by the rodless cylinder. Containing impurities, etc.
Solution: When internal or external leakage occurs in the rodless cylinder, we should first re-adjust the center of the piston rod and first ensure the coaxiality of the piston rod and the cylinder barrel;often Check whether the lubricator is working properly and ensure that the rodless cylinder is well lubricated;if the sealing ring and sealing ring are worn or damaged, replace the sealing ring and sealing ring in time;if there are impurities in the rodless cylinder, they need to be replaced in time. Remove impurities to ensure rod-freecylinderCan operate normally.
4. How to repair demagnetization of rodless cylinder
Cause of failure: When the rodless cylinder is used for a long time, it will cause demagnetization.
Solution: If there is a demagnetization problem, the magnet needs to be replaced in time.
5. How to adjust the vibration of the rodless cylinder
Cause of failure: When the rodless cylinder operates slowly, vibration will occur.
Solution: Use the speed regulating valve to adjust the speed.