1. Air filter: It is used to clean the air source and can filter the moisture in the compressed air to prevent moisture from entering the device with the gas.
2. Pressure reducing valve: Stabilizes the pressure of the air source to keep the air source in a constant state, which can reduce the damage to hardware such as valves or actuators due to sudden changes in the air source pressure. damage.
3. Oil mist device: lubricates the moving parts of the body and can lubricate parts that are inconvenient to add lubricating oil, greatly extending the service life of the body.
What does the gas source triplex include?
PneumaticTriple piece refers to three types of air filter (F), pressure reducing valve (R) and lubricator (L) The pressure reducing valve can stabilize the pressure of the air source and keep the air source in a constant state, which can reduce damage to hardware such as valves or actuators due to sudden changes in air source pressure. The filter is used to clean the air source and can filter the water in the compressed air to prevent water from entering the device with the gas.
The oil mist device can lubricate the moving parts of the machine body and lubricate the parts that are inconvenient to add lubricating oil, greatly extending the service life of the machine body. The air filter pressure reducing valve is light and small in design and easy to install. Therefore, it can be installed and used together with pneumatic transmitters, pneumatic regulators and other products. If the pressure reducing valve of the air filter is designed as a whole, it is called Two couplets.
Instructions for use of triple gas source
1. There are two ways of filter drainage: pressure difference automatic drainage and manual drainage. When draining manually, the water level must be drained before it reaches the level below the filter element.
2. Pressure adjustment method: first pull up the pressure reducing valve knob, turn it to the right to increase it, and turn it to the left to decrease it. When the pressure is adjusted, press down the rotating knob. Fixed for positioning. Pay attention to the adjustment process, gradually and evenly adjust to the required pressure value, and observe whether the reading of the pressure gauge is stable.
3. The oil mist device can only use 32# steam turbine oil of the same grade. The oil volume cannot exceed 80% of the oil cup. The oil volume is adjusted by the black knob on the top of the oil cup. It is marked with numbers from 0 to 9, where 0 is the minimum oil volume and 9 is the maximum oil volume. The rotation direction is uniformly from 0 to 9 and cannot be rotated from the 9-0 direction.
Gas source triplex maintenance
1. The filter element and water cup should be cleaned regularly.
2. The pressure regulating failure is inaccurate. Check whether the spring, valve core and balance spring of the pressure regulating device are damaged.
3. When a large amount of gas overflows from the overflow hole, check whether the rubber on the diaphragm and valve stem is damaged.
4. Clean regularly. You can use soapy water and clean water. Avoid using organic solvents such as acetone and toluene to clean plastic parts such as water cups and oil sight windows.
5. When assembling, apply an appropriate amount of butter or lubricating oil on the sliding parts and O-rings.