Gas solenoid valve How to open
Under normal circumstances, the valve is open if it is in a 90-degree position. It is a type of safety device and plays an important safety precaution role in gas pipelines. At the same time, the device also has a suction button. When danger occurs and an alarm is issued, this button can directly turn off the air source to prevent explosion accidents. After the alarm is cleared, you can use it normally by pulling down the extension handle.
For gas solenoid valve, it is composed of coil and push rod It is composed of magnets, etc., and uses coils and current to produce magnetism. It can automatically isolate gas when there is no open flame burning to avoid gas poisoning. In the event of an open flame burning, it can directly cut off the gas source to avoid an explosion.
p>
Gas What is the problem when the solenoid valve cannot open?
1. The solenoid valve itself has poor performance or is damaged and cannot be closed. Replace the solenoid valve with a new one according to the original model to ensure that it can close and close normally. That’s it.
2. The fault of the pulse ignition assembly causes the supply electromagnetic The driving voltage of the valve is not supplied normally. Just replace the pulse igniter of the same model.
3. The micro switch is damaged, causing pulse ignition If the solenoid valve is not working and has no voltage supply, and is damaged due to fretting, please replace it directly. When replacing, be sure not to lose the spring under the knob.
4. The battery power is insufficient and the solenoid valve cannot be driven to work. , if the battery power is insufficient, directly replace it with a brand new battery with sufficient power.
p>
The gas solenoid valve works well and bad sometimes , when it fails, it only ignites but the solenoid valve does not move
It is better to ask someone to repair it to prevent accidental danger. After replacing the solenoid valve, use strong soapy water to check for leaks. Do not be careless.
Insufficient battery power will lead to insufficient pulse ignition power. The magnetic pole will not attract, and the gas will not be able to enter. For built-in gas stoves, it is best to know the manufacturer. According to my understanding, there is no solenoid valve on the built-in gas stove, but a high-pressure ignition generator. You also said that you want a power-saving type. It's simple. Just connect a switch to the power cord. If you don't have to turn it off, it will save power. First, check the small circle in the middle to see if there is any fire. It may be that there is no fire, the thermocouple in the middle is not heated, and the protection function cannot be guaranteed. If there is fire in the middle of the damper, it can be used normally. The temperature of the thermocouple cannot be maintained and the protection circuit operates. The solenoid valve is closed, the stove is cut off, and the fire is naturally extinguished. The thermocouple is overoxidized or the feedback cable is connected incorrectly. If it is the former, the thermocouple needs to be replaced. If it is the latter, the cable needs to be re-spliced. As a side note, infrared stoves use ion flameout protection and do not have this fault. When getting a new stove, get an infrared stove.
The above isHow to open the gas solenoid valve, what is the problem if the gas solenoid valve cannot be opened Content introduction, If you want to know more relevant information, please log in to www.diancifa.cc.