What does port p of the solenoid valve represent, and what does port e a b represent?
Author:RinckSource:https://www.diancifa.cc/Update time:2024-11-13 09:46:22 Read:
What does port p of the solenoid valve represent, and what does port e a b represent? Answer: p is the air inlet of the air source, a is the air outlet 1, b is the air outlet 2, and e is the exhaust port. The five-position two-way valve has two exhaust ports, which are connected to a and b respectively;the four-position two-way valve a and b share one exhaust port. 2/3 two-position three-way solenoid valve structure (single electric control, direct-acting type) solenoid valve core has 2 positions and three pneumatic interfaces, as shown in Figure 1, P port is the air source interface, and A is the pneumatic Actuator interface, R is the exhaust port. 2/3 Two-position three-way solenoid valve structure (single solenoid control, direct-acting type) initial state (power loss): At this time, the solenoid valve loses power, the valve core is on the right side, A port is the same as R port, and the cylinder is exhaust status, P port is closed. 2/3 Two-position three-way solenoid valve structure (single solenoid control, direct-acting type) working status (energized): At this time, the solenoid valve is energized, the valve core is sucked to the left by the electromagnetic force, and port P is connected to port A. The air source leads to the cylinder from port A, and port R is closed;if power is lost, the valve core returns to the initial state in Figure 2 under the action of the spring. 2/5 two-position five-way solenoid valve structure (single electric control, direct-acting type) solenoid valve core has 2 positions and five air interfaces. Port P is the air source interface, and A and B are leading to the pneumatic execution interface, R and S are exhaust port 2/5 two-position five-way solenoid valve structure (single solenoid control, direct-acting type) initial state (power loss): At this time, the solenoid valve loses power, the valve core is on the right side, P The air source is connected to port A, and the air source enters the air chamber on one side of the cylinder through port A. Port B is connected to port S. The other side of the cylinder connected to port B is in exhaust state, and port R is closed. 2/5 Two-position five-way solenoid valve structure (single solenoid control, direct-acting type) working status (energized): At this time, the solenoid valve is energized, the valve core sucks to the left under the action of electromagnetic force, and the P port is connected to Port B is connected, and the air source enters the air chamber on the other side of the cylinder through port B. Port A is connected with port R. The side of the cylinder connected to port A is in exhaust state, and port S is closed. If power is lost, the valve core will return to the initial state in Figure 5 under the action of spring force. 2/5 two-position five-way solenoid valve structure (double electric control, direct-acting type) initial state: at this time, the solenoid valve has no power, the valve core is on either side of the left and right (this picture is on the right side), P port and A port The air source enters the air chamber on one side of the cylinder through port A, and port B is connected to port S. The side of the cylinder connected to port B is in the exhaust state, and port R is closed. The above is what the p port of the solenoid valve represents, and what does the e a b port represent? Content introduction, if you want to know more relevant information, please log in to www.diancifa.cc to view the Dianwei Pneumatic.