The most common faults and troubleshooting methods of pneumatic directional valves

Author:神威气动Source:http://www.diancifa.cc/Update time:2025-01-09 03:58:07 Read:
The main faults are poor operation and leakage. The main reasons are condensation water, dust, rust, poor lubrication, poor sealing ring quality, etc. in the compressed air.






























Loading...
Fault:Cause analysis:Processing method:
No action when powered on:Poor contact in the power supply wiring
The power supply voltage fluctuation is not within the allowable range
The coil is short-circuited or burned out
Connect the power cord
Adjust the voltage within the normal range
Replace the coil
Fluid cannot pass when the valve is opened: The fluid pressure or working pressure difference does not meet the requirements
The fluid viscosity or temperature does not meet the requirements
Dirt and impurities are mixed around the valve core and the moving iron core
The filter in front of the valve or the pilot valve hole is clogged
The working frequency is too high or the lifespan has expired
Adjust the pressure or working pressure difference or replace a suitable product
Replace a suitable product
Clean the interior, and a filter valve must be installed in front of the valve
Clean the filter or pilot valve hole in time
Change Product model or replace with new product
The fluid cannot be cut off when closing the valve:The fluid viscosity does not meet the requirements
The fluid temperature does not meet the requirements
The spring is deformed or has expired
The valve seat is defective or dirt adheres to it
The sealing gasket is detached, defective or deformed
The balance hole or The orifice is clogged
The operating frequency is too high or the lifespan has expired
Replace the appropriate product
Replace the appropriate product
Add a gasket or replace the spring
Clean, grind or update
Update and reassemble
Clean in time
Change the product model Or change to new products
External leakage:The pipe connection is loose
The outer seal of the pipe connection is damaged
Tighten the bolts or pipe threads
Replace the seals
Serious internal leakage:The fluid temperature does not meet the requirements
The pilot valve seat and main valve seat have impurities or defects
The pilot valve and main valve seals are detached or deformed
The spring assembly is poor, deformed or has expired life
Use The operating frequency is too high
Adjust the fluid temperature or replace
If necessary, clean or grind, repair or replace
Replace the seal
Replace the spring
Change the product model or replace with a new one
Excessive noise when power is on:Loose fasteners
Voltage fluctuations, not within the allowable range
The fluid pressure or working pressure difference is not suitable
The fluid viscosity does not meet the requirements
There are impurities on the armature suction surface
Tighten
Adjust to the normal range
Adjust the pressure or working pressure difference or replace the product
Replace with a suitable product
Clean in time