1. Ordinary solenoid valves only discharge fluid;pulse solenoid valves have a storage and release process.
2. Ordinary solenoid valve (Electromagnetic valve) is an industrial equipment controlled by electromagnetism. It is an automation basic component used to control fluids. It is an actuator and is not limited to hydraulic and pneumatic. . Used in industrial control systems to adjust the direction, flow, speed and other parameters of the medium. And Pulse solenoid valve Refers to a diaphragm valve that is controlled by an electromagnetic or pneumatic pilot valve and can open and close a high-pressure air source to generate pulses in an instant. The air flow passes through the air resistance and the delay effect of the air volume allows the input of a long signal. Valve type that changes into pulse signal.
The difference between solenoid valves and pulse valves
1. The solenoid valve only discharges fluid;the pulse valve has a storage and release process.
2. Electromagnetic valve is an industrial equipment controlled by electromagnetism. It is a basic component of automation used to control fluids. It is an actuator and is not limited to hydraulic and pneumatic. Used in industrial control systems to adjust the direction, flow, speed and other parameters of the medium.
< strong>Solenoid valve can be matched with different circuits to achieve the desired control, and the control accuracy and flexibility can be guaranteed. There are many types of solenoid valves. Different solenoid valves play a role in different positions of the control system. The most commonly used ones are one-way valves, safety valves, directional control valves, speed regulating valves, etc.
3. Pulse valve refers to a diaphragm valve that is controlled by an electromagnetic or pneumatic pilot valve and can open and close a high-pressure air source to generate pulses in an instant. The delay function of the capacitor makes the input long signal into a pulse signal.
Working requirements of pulse valve:
Working pressure: Z-type valve: 0.4~0.6Mpa
Y-type valve: 0.2~0.6Mpa ZM-type valve: 0.4~0.6Mpa.
Gas source medium: clean gas with temperature <55℃, oil removal and water treatment, filtration accuracy <5μm and adjustable pressure.
Usage environment:
1. Temperature: -25℃~55℃55℃~180℃.
2. The relative humidity of the air does not exceed 85%.
3. The protection level complies with IP64.
Diaphragm life: 1 million times.
Pulse valve life span: five years under the conditions of standardized installation, correct use, and reasonable maintenance.