Further Narrow Down
Category
slow opening valve
Slow-start valves are used to safely build up pressure in pneumatic systems and serve as safety protection. The air inlet is connected to the input P of the slow-start valve. If the coil is energized, the three-port two-position valve opens. At this time, a small amount of air passes through the throttle valve to the output A, causing the system pressure to slowly build up;when the output pressure is equal to the input When the pressure is half, the slow-start valve is fully opened, and the flow rate reaches its highest value at this time. When the coil is powered off, the air inlet P is closed, and the air returns to the R port through the one-way valve and is quickly discharged. The system pressure drops to zero, which provides safety protection for the entire system.
Category:slow opening valve
Slow-start valves are used to safely build up pressure in pneumatic systems and serve as safety protection. The inlet air is connected to the input P of the slow-start valve. If the coil is energized, the three-port two-position valve opens. At this time, a small amount of air passes through the throttle valve to the output A, causing the system pressure to slowly build up;when the output pressure is equal to the input When the pressure is half, the slow-start valve is fully opened, and the flow rate reaches its highest value at this time. When the coil is powered off, the air inlet P is closed, and the air returns to the R port through the one-way valve and is quickly discharged. The system pressure drops to zero, which provides safety protection for the entire system. Category: Slow opening valve, Brand: Yadeke, Series: GV
Click on the order code to learn more about each product number
Order code | Product Code | Reference standard price (excluding tax) | Reference standard price (including tax) | Estimated delivery | Quantity | ||||
---|---|---|---|---|---|---|---|---|---|
203257 | GV40015NBI | PT1/2 | Comes with stand | No schedule | DC24V | $26.62 | $30.08 | One-year return guarantee | |
203165 | GV20006C1A | PT1/8 | Comes with stand | Schedule | AC220V | $20.83 | $23.54 | One-year return guarantee |
Slow-start valves are used to safely build up pressure in pneumatic systems and serve as safety protection. The inlet air is connected to the input P of the slow-start valve. If the coil is energized, the three-port two-position valve opens. At this time, a small amount of air passes through the throttle valve to the output A, causing the system pressure to slowly build up;when the output pressure is equal to the input When the pressure is half, the slow-start valve is fully opened, and the flow rate reaches its highest value at this time. When the coil is powered off, the air inlet P is closed, and the air returns to the R port through the one-way valve and is quickly discharged. The system pressure drops to zero, which provides safety protection for the entire system. Category: Slow opening valve, Brand: Yadeke, Series: GV
Product knowledge
- NPT, PT, R, G thread standard size table_pipe thread standard size table_taper pipe thread comparison table specification table
- Sunway Cylinder Solenoid Valve Joint Air Pipe Parameters and Dimensions Selection Manual 2022 Latest Edition
- AirTAC cylinder 3D three-dimensional model diagram selection manual product software 2023 download
- How to calculate the theoretical output pressure and thrust output of the cylinder and the comparison table
- SMC cylinder 3D three-dimensional model diagram selection sample manual software 2021 download
- Several important parameter diagrams for cylinder model and size selection
- How to adjust the pressure reducing valve? Pressure reducing valve installation diagram
- Top ten cylinder brands, what domestic brands of cylinders are there, ranking list of the top 5 cylinder brands
- How to read kilograms and degrees on a pressure gauge with illustrations
- SC standard cylinder size table
- Cylinder internal structure diagram, detailed introduction of cylinder structure composition
- Internal structure diagram and working principle of electric cylinder
- What are the meanings of AirTAC cylinder model parameters?
- How to wire the pressure sensor? Attached wiring diagram
- Working principle of magnetic switch, magnetic switch wiring diagram
- What is a cylinder sensor, how the cylinder sensor works and the wiring diagram
- How to connect the solenoid valve to the double-stroke cylinder, the working control principle diagram of the double-stroke cylinder
- Where is the carbon canister solenoid valve located? Can the carbon canister solenoid valve be replaced by myself?
- Which cylinder is the air inlet and outlet? How to distinguish the cylinder air inlet and air outlet?
- Causes and solutions of 16 cylinder fault phenomena