How to install the temperature control solenoid valve? What are the symptoms of a broken temperature control solenoid valve?

Author:RinckSource:https://www.diancifa.cc/Update time:2024-10-25 04:01:58 Read:

Temperature controlled electromagnetic How to install the valve


1. In the pipeline system, The diameter of the solenoid valve should be smaller than the diameter of the main pipeline valve.

2. Before installing the solenoid valve, the pipeline must be cleaned clean. It is recommended to install a filter in front of the valve and a trap in the steam pipe.

3. When the solenoid valve fails, in order to Isolate the solenoid valve in time and ensure the normal operation of the system. It is best to install a bypass device.

4. When installing, the solenoid valve coil is upward, and Maintain a vertical position. The arrow or mark on the solenoid valve should be consistent with the flow direction of the pipe. It should not be installed in a place with splashing or leaking water.

5. Before installation, pay attention to see clearly product label and carefully read the instruction manual to determine whether the product meets the conditions for use.

6. The valve cannot be installed low in the pipeline. recess to prevent steam condensation, impurities, etc. from settling in the valve and impeding action.

7. Cannot be used in explosion-risk situations.

8. When the pipeline rigidity is insufficient, It is recommended to fix the pipe in front of the valve with a bracket to avoid vibration caused by the solenoid valve during operation.

9. The working medium of the solenoid valve should be clean and free of moisture. Particulate impurities, dirt on the surface of the solenoid valve internal parts and the filter need to be cleaned regularly.

10. Pressure must be installed on the pipes before and after the solenoid valve gauge to observe pipeline pressure.

How to install the temperature control solenoid valve, symptoms of a broken temperature control solenoid valve

The temperature control solenoid valve is broken


The main symptoms include: water cannot enter or water always enters;water temperature and water position cannot be displayed;cannot work after power on, cannot be turned off, etc. BecauseSolenoid valve is a component used to control the water inlet of the machine. If it is broken, it may cause the water to be unable to flow or the water flow will not stop. If it is damaged, it must be promptly Replace it to avoid affecting your life.


The above isHow to install the temperature control solenoid valve, the symptoms of a broken temperature control solenoid valve Content introduction, If you want to know more relevant information, please log in to www.diancifa.cc.