How to use mhz2-16d cylinder, how to install mhz2-16d cylinder
1. When the circuit pressure is low due to an emergency, the clamping force may be reduced and the workpiece may fall. In order to avoid injury to the human body or damage to the equipment, anti-fall protection must be installed device.
2. Do not use pneumatic fingers under excessive external force and impact.
3. If the single-action type is only clamped by spring force, please discuss it with our company.
4. Install and fix the pneumatic fingerCylinderBe careful not to drop, collide or damage it.
5. When fixing the clamp accessories, please do not twist the clamp jaws.
6. The pneumatic finger has the following installation methods, and the tightening screw tightening torque must be within the torque range specified in the table below. If it is too large, it will cause poor operation, and if it is too small, it will cause malfunction. Position deviation and drop.
7. Installation method of clamping jaw accessories:
Pay special attention when installing the clamp accessories. You can only use an open-end wrench to clamp the clamp, and then use an internal hexagonal wrench. Do not clamp the body directly and then tighten the screw, otherwise Parts can easily be damaged.
8. Confirm that no additional external force is exerted on the clamping jaw. Lateral loads act on the clamping jaws, resulting in impact loads, causing shaking and damage to the clamping jaws. Set the gap so that the pneumatic finger will not collide with the workpiece and accessories at the end of the stroke.
8.1. The end of the stroke when the pneumatic fingers are open;
8.2. End of pneumatic finger movement stroke;
8.3. Reverse the action state.
When reversing, the position of the workpiece must be clamped accurately, otherwise the workpiece may collide with the surrounding environment during the reversal state and generate an impact load. When the workpiece is inserted, the center line must be coaxial and cannot be eccentric to avoidmhz2-16d cylinder generates additional external force. It is particularly required that during the test run, the manual action and pressure must be reduced to run it at a low speed, and it must be confirmed to be safe and free of impact.
9. Please use a speed regulating valve to adjust the opening and closing speed of the clamping jaw so that it is not too fast.
10. People are not allowed to enter the moving path of the pneumatic finger and no objects are allowed to be placed.
11. When removing the pneumatic finger, make sure that the workpiece is not clamped and discharge the compressed air before removing it.
The above ismhz2-16d How to use the cylinder, how to install the mhz2-16d cylinderContent introduction, if you want to know more related information, please log in to Sunway Pneumatic View at www.diancifa.cc.