Use and maintenance of Airtac air source processor
1. The working medium should use clean and dry compressed air, and Blow out the air in the piping fully to prevent impurities from being brought into the system and causing malfunction of the cylinder and valves
. If lubrication is needed, add a mist to the piping system. The recommended lubricating oil is transparent No. 1 oil. (ISOVG32);
2. After the system is running normally, check the working condition of the air filter and oil mist regularly, drain the water (except for automatic drainage) and refuel in time;
3. When the cylinder and valve are not used for a long time, pay attention to the minimum operating frequency of 1 time/30 days;
4. Always check the operation of various pneumatic components and check whether the connecting fastening screws are loose? Is there any damage or leakage to the seal of the component?
Promptly handle any problems found;
5. During maintenance, the air source must be turned off in advance and the compressed air in the pipeline system must be emptied before repair work can be carried out to prevent Accident occurred
;
6. When components are inspected and reassembled, the parts must be cleaned and impurities cannot be brought into the system.